⚓ Keel

← Back to diagram

#3

M30 Replace? 1/5 — no

Nautor comment

Nothing to do but clean better the thread.

Bolt dimensions

D2 — Total bolt height
76.25 mm
D1 — Lead to thread
25 mm
H1 — Hull hole depth
44.3 mm
H2 — Keelson to plate
32.02 mm
Plate thickness (calc.)
12.28 mm
Keel width at station
13 in

D2 is the bolt's total height, from the head/tip down to the top of the lead. D1 is the height from the lead up to where the threads start. H1 is how deep the hole in the hull is where the bolt sits. H2 is the thickness from the bottom of the keelson to the bottom of the internal plate. Plate thickness is calculated as H1 minus H2. Keel width is measured across the bolt centers at this bolt's station.

Backing plate

One-hole plate
Height (fore/aft)
91 mm
Width (athwartships)
90.93 mm (3.58 in)
Depth (thickness)
6.28 mm
Hole diameter
32 mm
Condition
Flat

Proof Test / Fixture

Starting proof-test stack — a calculated starting point, not an approved dimension. H1 is remeasured in the field before every test.

Baseline H1
44.3 mm
Calculated starting height
44.34 mm
Delta
0.04 mm
Latest result
PASS

Disposition: Retain existing bolt / thread

Proof test record Attempt 1 · PASS · Retain existing bolt / thread

Test Attempts

Attempt 1 PASS

Pre-Test Inspection

Acceptable

Acceptable

Yes

Yes

—

—

Fixture Actually Used

—

44.71

Final stack used (specific components)
H52 qty

3

H25 qty

1

H10 qty

0

—

Proof Test

Lubricated

Tap Magic

—

254

No

—

254

Pass

Failure/concern observed

—

—

Disposition

Retain

—

—

Machining / Re-Threading

—

—

—

—

—

—

—

—

—

—

—

—

Extension / Prosthesis

—

—

—

—

—

—

—

—

—

—

—

Final Installation

—

—

—

—

—

—

—

—

—

—

—

—

Sign-Off / Traceability

—

—

—

—