#8
Nautor comment
Install a bolt extension, a sort of prosthesis that rebuilds the bolt, according to the procedure explained in Appendix 1 at the end of this document.
Bolt dimensions
- D2 — Total bolt height
- 78.12 mm
- D1 — Lead to thread
- 29 mm
- H1 — Hull hole depth
- 36.04 mm
- H2 — Keelson to plate
- 32.52 mm
- Plate thickness (calc.)
- 3.52 mm
- Keel width at station
- 14.5 in
D2 is the bolt's total height, from the head/tip down to the top of the lead. D1 is the height from the lead up to where the threads start. H1 is how deep the hole in the hull is where the bolt sits. H2 is the thickness from the bottom of the keelson to the bottom of the internal plate. Plate thickness is calculated as H1 minus H2. Keel width is measured across the bolt centers at this bolt's station.
Backing plate
Two-hole plate, shared with #9- Height (fore/aft)
- 80 mm
- Width (athwartships)
- 241.3 mm (9.5 in)
- Depth (thickness)
- 8 mm
- Hole diameter
- 36 mm
- Condition
- Flat
Proposed extension — profile cutaway · v2 (Nov 12, 2026)
To scale, section through the bolt centreline. Heights in mm above the lead keel baseline. Fiberglass + 8 mm backing plate taken from this bolt's H1. The air gap between the keel and hull faces isn't measurable here (about 0–7 mm); it's drawn at 0, which puts the plate lowest. The design clears the plate either way, and the stud gives full nut engagement up to a 7 mm gap at #8.
Before — #8 as it stands
After — with extension · v2 (Nov 12, 2026)
Extension: XM-19 HS, ASTM A479 — MTR required; weld plate 316 stainless, tack welded with 316 stainless filler. M30 nut, 23 mm, seated on the backing plate with no washer (drawn across corners). The original bolt's thread starts at D1. Excavation 75.7 mm square (63 + ½″, the original plate's pocket widened chiselling it out), round the 63 mm plate. Assumed: the fiberglass hole is enlarged to Ø52 (about 1 mm clearance on the Ø50 body).
Strength vs. the A4-70 rod
Rod (M30, A4-70, As 561 mm²): yields at 252 kN, breaks at 392 kN. Each cell is yield / break in kN, with % of the rod's. The stud is the same thread as the rod, so the bar needs at least Rp0.2 450 MPa and Rm 700 MPa.
| Section | 316 annealed (ASTM A479) 205/515 MPa · weaker than the rod | XM-19 annealed (Nitronic 50 / Aquamet 22, A479) 380/690 MPa · weaker than the rod | XM-19 high strength (Nitronic 50 HS / Aquamet 22HS) 725/930 MPa · as strong as the rod |
|---|---|---|---|
| Body round the internal thread | 258 (102%) / 647 (165%) | 478 (189%) / 867 (221%) | 911 (361%) / 1,169 (298%) |
| Shoulder (narrowest) | 145 (57%) / 364 (93%) | 269 (106%) / 488 (124%) | 512 (203%) / 657 (168%) |
| Stud neck (plain, Ø30) | 145 (57%) / 364 (93%) | 269 (106%) / 488 (124%) | 512 (203%) / 657 (168%) |
| Stud thread | 115 (46%) / 289 (74%) | 213 (84%) / 387 (99%) | 406 (161%) / 521 (133%) |
| Internal thread stripping | — / 739 (188%) | — / 990 (252%) | — / 1,334 (340%) |
| Stud thread stripping in the nut | — / 360 (92%) | — / 482 (123%) | — / 650 (166%) |
Bold: the weakest section. The shoulder's tightest fillet radius is 3.6 mm (Kt ≈ 1.8); on the larger unthreaded section that peaks at about 1.4× the thread's nominal stress, below a cut thread root's (Kt about 3–4), so the transition isn't the weak point. The stud thread stops at a 3 mm plain neck at Ø30 and washes out (no undercut); full thread from 31.8 above the keel. Spec minimums, not measured values; thread stripping at 0.6 Rm.
Machine-shop upload set (M30, qty 2)
Extension: STEP · IGES · STL · Drawing (PDF) · FreeCAD · STEP, threaded · STL, threaded
Weld plate: Cut DXF · STEP · IGES · STL · Drawing (PDF)
Loading 3D model…
Couldn't load the 3D model.
Proof Test / Fixture
Starting proof-test stack — a calculated starting point, not an approved dimension. H1 is remeasured in the field before every test.
- Baseline H1
- 36.04 mm
- Calculated starting height
- 35.99 mm
- Delta
- -0.05 mm
- Latest result
- FAIL
Disposition: Install extension
Proof test record Attempt 1 · FAIL · Install extension
Test Attempts
Attempt 1 FAIL
Pre-Test Inspection
Acceptable
Corroded
Yes
Yes
—
Heavily corroded
Fixture Actually Used
—
36.24
1
0
0
—
Proof Test
Lubricated
Tap Magic
—
—
—
—
—
Fail
—
—
Disposition
Install Extension
—
—
Machining / Re-Threading
—
—
—
—
—
—
—
—
—
—
—
—
Extension / Prosthesis
—
—
—
—
—
—
—
—
—
—
—
Final Installation
—
—
—
—
—
—
—
—
—
—
—
—
Sign-Off / Traceability
—
—
—
—